Omnes Categoriae

Controlis inversoris DC

Pagina Principalis >  Products >  Controlis inversoris DC

Modulus Controlis Agens BAC04

Modulus Controlis Agens BAC04

Introductio: Modulus integratus controlis motoris seriei BAC04 compressoris coniungit functionem motoris compressoris et functionem controlis principalis in unum modulum cum parvo magnitudine, alta efficientia et multis portis.
Applicatio: 1, Mini Commercial AC; 2, Humidificator; 3, Siccitas; 4, systema stoccationis energiae & dissipationis caloris; 5, Refrigerator;
Caracteristicae: 1, Motor 1-3HP;
2, Ventilator BLDC unius viae;
3, Sensus caloris sex viarum;
4, 6 via deficiendi input;
5, 8 via 5A relais;
6, 1 via 30A relais;
7, 1 via 0-10VDC;
8, 2 via RS485;
9, bivium EXV;
10, bivium sensor pressurae.

  • Conspectus
  • Inquisitio
  • Producta Relata

Introductio
BAC04A est ad integrandam controlandamque partem cum unitate externa et compressore coniectum. Hoc modulum potest adhiberi pro compressore DC inverter et turbine BLDC. Modulus noster multum est flexibilis, usor potest adhibere
nostrum firmware praedefinitum, itemque supportat programmatum DIY super basim nostrae firmware. Modulus controlandus supportat frigus \/calorem
\/Exsiccatio \/aer fresh \/control remotus function.
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board details
Technical Data Sheet
Mensuratio dolor
-20~99℃ RH≤90% (non condensed)
Rangus controllandi
-20~99℃ RH≤90% (non condensed)
Ingressus potentiae
220VAC 50Hz/60Hz
Temperatus imperium accurate
±0.5℃
Porta EXV/EVI
4-via
Output relais
17-via
Sensorem temperaturae
6pcs (5pcs normalis sensor +1pc sensor altae temperaturae)
Pressura Sensor
1*sensor altissimi pressurae +1*sensor infimae pressurae
Input defectus
9
Ingressus alarmae externae
1
Portus compressoris
Configuratio duplex compressoris
Modulus supellectilis
188*124*57cm
Typus senioris
Sensorem NTC 3950k et 3470k
Consumptio potentiae
<10w
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board details
                                              Caracteres
Functio memoriae ad defectum potentiae
Entrata externa defectus (Alarma ignis)
Modus: Calefaciens \/refrigescens \/exsiccans
Remotum imperium
Control EEV (cum inclusa EVI EEV)
Vicis in / off
Control singuli vel duplex compressoris
Protectio a pressione alta
Protocolum Modbus
Protectio supercargi ventilatoris
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board manufacture
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board factory
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board details
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board supplier
Bandary R32 R410 Vrf System Air Cooler DC inverter circuit boards compressor inverter board controller heat pump Control Board manufacture

Concinite

Email Address *
Nomen
Numerus Telephonicus
Company Name
Missiva *