All Categories

DC inverter control

Home >  Products >  DC inverter control

Custom Inverter Ac Pcb Board Led Display Circuit Board Assembly Communication Pcba DC Inverter Air Conditioning Bandary/odm RF-4

Custom Inverter Ac Pcb Board Led Display Circuit Board Assembly Communication Pcba DC Inverter Air Conditioning Bandary/odm RF-4

  • Overview
  • Inquiry
  • Related Products

Indoor Unit
Introduction

Indoor unit BAC02B is designed to communicate with outdoor unit BAC01, then transfer the user setting mode, Setting temperature, room temperature to outdoor unit, and receive the running status from outdoor unit.
Sensor Input Data- BAC02B
Item
Port
Name
Value
1
TH1
Tr:return temperature sensor
10K
2
TH2
Tin:fan coil input sensor
10K
3
TH3
Tou:fan coil outlet sensor
10K
4
TH4-TH6
reservation
Input / Output ports Data- BAC02B
Item
Port
Description
Remark
1
CN485
RS485
Connect to outdoor unit
2
CN12
Transformer initial port
Connect to transformer
3
CN13
Transformer secondary port
Connect to transformer
4
CN15
SLM FC264
HMI
5
CN17
EEV port
Connect to EEV
6
CN19
AC/DC indoor fan port
Adjustment RPM of DC FAN
7
CN21
Hi fan speed output
8
CN22
Medium fan speed output
9
CN25
Power supply output
Connect to AC/DC fan
10
CN27
PUMP output
11
L
L
Power input 220vac
12
N
N
Power input 220vac
ON/OFF Input Data- BAC02B
Item
Port
Description
Remark
1
CN6
Room card function
OCC function
2
CN7
External fault input
NO-Fault NC-Normal
3
CN9
Water switch
Control water switch